Radiation protection in pediatric radiology

Results of a survey among Dutch hospitals

Auteurs
Harmen Bijwaard, Doreth Valk en Ischa de Waard-Schalkx
Soort object
Artikel
Datum
2016
Samenvatting
Abstract—A survey about radiation protection in pediatric radiology was conducted among 22 general and seven children’s hospitals in the Netherlands. Questions concerned, for example, child protocols used for CT, fluoroscopy and x-ray imaging, number of images and scans made, radiation doses and measures taken to reduce these, special tools used for children, and quality assurance issues. The answers received from 27 hospitals indicate that radiation protection practices differ considerably between general and children’s hospitals but also between the respective general and children’s hospitals. It is recommended that hospitals consult each other to come up with more uniform best practices. Few hospitals were able to supply doses that can be compared to the national Diagnostic Reference Levels (DRLs). The ones that could be compared exceeded the DRLs in one in five cases, which is more than was expected beforehand.